chara:operating_procedures [2018/07/03 16:40]
jones
chara:operating_procedures [2018/07/03 16:56]
jones
Line 2: Line 2:
  
 __**OBSERVING PROCEDURES**__\\  __**OBSERVING PROCEDURES**__\\ 
-[[chara:operating_procedures#labprotocol|Lab Protocol]]\\ [[/Operating%20Procedures#chapter.labprep|Preparations in the Lab Prior to Observing]]\\ [[/Operating%20Procedures#chapter.controlroom|Setting up Computer in the Control Room]]\\ [[/Text%20Commands%20for%20CHARA%20GUIs|Text Commands for CHARA GUIs]]\\ [[/Operating%20Procedures#chapter.observing_conditions|Observing Conditions]]\\ [[/Operating%20Procedures#GoingOnSky|Going on Sky]]\\ [[/Operating%20Procedures#ShuttingDown|Procedure for Shutting Down the Array]]\\ \\ __**SUPPLEMENTAL INFORMATION**__\\ [[/Remote%20Observing|Remote Observing]]\\ [[/Power%20Outage|Power Outage]]\\ [[file/view/Co-Phasing_with_CHARA.pdf/615228791/Co-Phasing_with_CHARA.pdf|Co-phasing with the CHARA phase reference]]\\ [[/file/view/Labao%20with%20Starlight%20v4.pdf/627133425/Labao%20with%20Starlight%20v4.pdf|Using Labao with Starlight]]\\ [[/file/view/S2_New_Finder_Camera-r1.docx/615406377/S2_New_Finder_Camera-r1.docx|New S2 Finder Instructions]]\\ [[/Night-time%20POP%20Changes|Night-time POP Changes]]\\ __[[/Azimuth%20coud%C3%A9%20alignments|Azimuth coudé alignments]]__\\ [[/file/view/Tiptilt%20Splitters%20Change.pdf/368145106/Tiptilt%20Splitters%20Change.pdf|Tip-tilt Splitters Change]]\\ [[/Trouble%20Shooting|Trouble Shooting]]\\ [[/horizons|Telescope Horizon Limits]]\\ [[/Restarting%20Servers|Restarting Servers]]\\ \\ __**INSTRUMENTS**__\\ [[/Instruments|Instrument Manuals]]\\ [[/Instruments|Observing Logs]]\\ [[/FringeOffsets|Recent fringe offsets]]\\ [[/Instruments|Software setup for specific instruments]]\\ [[/Classic%20Faint%20Object%20Procedures|Classic Faint Object Procedures]]\\ \\ __**DOCUMENTATION TO BE UPDATED**__\\  Note: the information contained in these wiki pages needs to be incorporated into the documentation in the CVS tree.\\ \\ CHARA Array Operating Procedures\\  Copyright © 2005-2018 The CHARA Team\\  Last updated: 2018-01-11\\ \\ \\ \\ {{/file/view/Picture_21.png/308555522/247x275/Picture_21.png|Picture_21.png}}\\ \\ \\ {{/file/view/Picture_22.png/308555456/800x304/Picture_22.png|Picture_22.png}}\\ \\ \\ \\ \\ _\\ \\ \\ **Chapter 1: **\\ ** LAB PROTOCOL**\\ \\ {{/file/view/Picture_28.png/213864986/80x125/Picture_28.png|Picture_28.png}}{{/file/view/Picture_29.png/213865030/149x54/Picture_29.png|Picture_29.png}}\\ \\ __1.1 Lab Rules Intro__\\ \\  The CHARA optics lab is a building within a building and is intended to provide thermal and vibrational stability. The main goal of the CHARA lab rules is to keep all optics and equipment safe from any hazards. The crucial issue being misalignment of anything. The amount of dust and dander must be kept to a minimum.\\ \\ __ 1.2 The Metrology Laser__\\ \\  A high-powered infrared laser is used for the delay line metrology. This is an eye hazard, so before entering the lab check to make sure the red light above the door is not on. If the laser is activated, it is a must to put on IR-protective goggles. If you are not sure, wear the goggles.\\ \\ __ 1.3 General Lab Rules__\\ \\ Please remember that:\\  Procedures in the lab must be followed closely and failure to follow these rules will result in loss of lab privileges.\\ \\  • Before entering the lab, you must have a reason or tasks at hand.\\  • Lab booties/shoe covers must be worn by all. Throw out booties that have holes in them. The traction tape on the steps are particularly rough on booties so examine them before and after using them.\\  • Proper clothing is also important. Loose hanging jackets or garments can snag on mirrors or other exposed equipment and are better left outside of the lab until you are finished.\\  • Please be alert and move slowly and cautiously.\\  • When entering the lab make sure to walk across the sticky floor mat. If the mat isn’t sticky, remove the top layer. If this is close to the final layer please notify the staff.\\  • No more than three people are allowed in the lab at once unless it is 3 to 4 hours before observing time or there is some pressing need. Many bodies can create unwanted atmospheric effects. Besides, with too many people, it is too easy to bump into each other and the equipment.\\  • If you bump, hit, move or just tap anything in the slightest way, let us know.\\  • Never touch anything you have not been trained to use. If ever in any doubt, leave it alone and get someone who knows.\\  • Any unusual sounds, sights, movement of equipment, etc., should be noted.\\  • You must know the path of the laser beams, metrology or alignment. Stay out of their way especially right before observing. If you must go into the lab during this time don’t forget to put on IR-protective goggles.\\  • Access and use of the lab requires training. If a piece of equipment does not appear to be operating properly let us know immediately. Also if you are uncertain about a lab procedure or a step in the alignment sequence contact us before proceeding.\\ • When leaving the lab any time of the day, remember to turn off all lights (fluorescent and incandescent). Lights left on generate unnecessary heat in the lab.\\ \\ [[/Operating%20Procedures|Back to Main Menu]]\\ \\ \\ **Chapter 2: **Version 2. August 27, 2012 by Judit, Version 3 January 2015 by Norm, Version ? October 2017 by Norm\\ **PREPARATIONS ****IN THE LAB ****PRIOR TO OBSERVING**\\ \\ These are routine tasks to be performed in and around the lab every evening to prepare the array for regular observations.\\ \\ __2.1 Starting the vacuum pump for the light pipes__\\ Go into vacuum pump shack\\ +[[chara:operating_procedures#lab_protocol|Lab Protocol]]\\ [[/Operating%20Procedures#chapter.labprep|Preparations in the Lab Prior to Observing]]\\  
 +[[/Operating%20Procedures#chapter.controlroom|Setting up Computer in the Control Room]]\\  
 +[[/Text%20Commands%20for%20CHARA%20GUIs|Text Commands for CHARA GUIs]]\\  
 +[[/Operating%20Procedures#chapter.observing_conditions|Observing Conditions]]\\  
 +[[/Operating%20Procedures#GoingOnSky|Going on Sky]]\\  
 +[[/Operating%20Procedures#ShuttingDown|Procedure for Shutting Down the Array]]\\  
 +\\  
 +__**SUPPLEMENTAL INFORMATION**__\\  
 +[[/Remote%20Observing|Remote Observing]]\\  
 +[[/Power%20Outage|Power Outage]]\\  
 +[[file/view/Co-Phasing_with_CHARA.pdf/615228791/Co-Phasing_with_CHARA.pdf|Co-phasing with the CHARA phase reference]]\\  
 +[[/file/view/Labao%20with%20Starlight%20v4.pdf/627133425/Labao%20with%20Starlight%20v4.pdf|Using Labao with Starlight]]\\  
 +[[/file/view/S2_New_Finder_Camera-r1.docx/615406377/S2_New_Finder_Camera-r1.docx|New S2 Finder Instructions]]\\  
 +[[/Night-time%20POP%20Changes|Night-time POP Changes]]\\  
 +__[[/Azimuth%20coud%C3%A9%20alignments|Azimuth coudé alignments]]__\\  
 +[[/file/view/Tiptilt%20Splitters%20Change.pdf/368145106/Tiptilt%20Splitters%20Change.pdf|Tip-tilt Splitters Change]]\\  
 +[[/Trouble%20Shooting|Trouble Shooting]]\\  
 +[[/horizons|Telescope Horizon Limits]]\\  
 +[[/Restarting%20Servers|Restarting Servers]]\\  
 +\\  
 +__**INSTRUMENTS**__\\  
 +[[/Instruments|Instrument Manuals]]\\  
 +[[/Instruments|Observing Logs]]\\  
 +[[/FringeOffsets|Recent fringe offsets]]\\  
 +[[/Instruments|Software setup for specific instruments]]\\  
 +[[/Classic%20Faint%20Object%20Procedures|Classic Faint Object Procedures]]\\  
 +\\  
 +__**DOCUMENTATION TO BE UPDATED**__\\   
 +Note: the information contained in these wiki pages needs to be incorporated into the documentation in the CVS tree.\\  
 +\\  
 +CHARA Array Operating Procedures\\   
 +Copyright © 2005-2018 The CHARA Team\\   
 +Last updated: 2018-01-11\\  
 +\\  
 +\\  
 +\\  
 +{{/file/view/Picture_21.png/308555522/247x275/Picture_21.png|Picture_21.png}}\\  
 +\\  
 +\\  
 +{{/file/view/Picture_22.png/308555456/800x304/Picture_22.png|Picture_22.png}}\\  
 +\\  
 +\\  
 +\\  
 +\\  
 +_\\  
 +\\  
 +\\  
 + 
 +====Lab Protocol==== 
 +\\ \\ {{/file/view/Picture_28.png/213864986/80x125/Picture_28.png|Picture_28.png}}{{/file/view/Picture_29.png/213865030/149x54/Picture_29.png|Picture_29.png}}\\ \\ __1.1 Lab Rules Intro__\\ \\  The CHARA optics lab is a building within a building and is intended to provide thermal and vibrational stability. The main goal of the CHARA lab rules is to keep all optics and equipment safe from any hazards. The crucial issue being misalignment of anything. The amount of dust and dander must be kept to a minimum.\\ \\ __ 1.2 The Metrology Laser__\\ \\  A high-powered infrared laser is used for the delay line metrology. This is an eye hazard, so before entering the lab check to make sure the red light above the door is not on. If the laser is activated, it is a must to put on IR-protective goggles. If you are not sure, wear the goggles.\\ \\ __ 1.3 General Lab Rules__\\ \\ Please remember that:\\  Procedures in the lab must be followed closely and failure to follow these rules will result in loss of lab privileges.\\ \\  • Before entering the lab, you must have a reason or tasks at hand.\\  • Lab booties/shoe covers must be worn by all. Throw out booties that have holes in them. The traction tape on the steps are particularly rough on booties so examine them before and after using them.\\  • Proper clothing is also important. Loose hanging jackets or garments can snag on mirrors or other exposed equipment and are better left outside of the lab until you are finished.\\  • Please be alert and move slowly and cautiously.\\  • When entering the lab make sure to walk across the sticky floor mat. If the mat isn’t sticky, remove the top layer. If this is close to the final layer please notify the staff.\\  • No more than three people are allowed in the lab at once unless it is 3 to 4 hours before observing time or there is some pressing need. Many bodies can create unwanted atmospheric effects. Besides, with too many people, it is too easy to bump into each other and the equipment.\\  • If you bump, hit, move or just tap anything in the slightest way, let us know.\\  • Never touch anything you have not been trained to use. If ever in any doubt, leave it alone and get someone who knows.\\  • Any unusual sounds, sights, movement of equipment, etc., should be noted.\\  • You must know the path of the laser beams, metrology or alignment. Stay out of their way especially right before observing. If you must go into the lab during this time don’t forget to put on IR-protective goggles.\\  • Access and use of the lab requires training. If a piece of equipment does not appear to be operating properly let us know immediately. Also if you are uncertain about a lab procedure or a step in the alignment sequence contact us before proceeding.\\ • When leaving the lab any time of the day, remember to turn off all lights (fluorescent and incandescent). Lights left on generate unnecessary heat in the lab.\\ \\ [[/Operating%20Procedures|Back to Main Menu]]\\ \\ \\ **Chapter 2: **Version 2. August 27, 2012 by Judit, Version 3 January 2015 by Norm, Version ? October 2017 by Norm\\  
 +====PREPARATIONS IN THE LAB PRIOR TO OBSERVING==== 
 + \\ \\ These are routine tasks to be performed in and around the lab every evening to prepare the array for regular observations.\\ \\ __2.1 Starting the vacuum pump for the light pipes__\\ Go into vacuum pump shack\\ 
  
   * flip on power switch for pump (wait for blower to go on)   * flip on power switch for pump (wait for blower to go on)
Line 88: Line 139:
   * If using CLASSIC or CLIMB, turn on the black box above the NIRO computer, and then turn on the silver box below it on the same cart.   * If using CLASSIC or CLIMB, turn on the black box above the NIRO computer, and then turn on the silver box below it on the same cart.
   * After lab is completely setup, you need to take off tiptilt cover, but do so with only the dim lights on and the laser shutter closed >> you don't want to blast CCD with light.   * After lab is completely setup, you need to take off tiptilt cover, but do so with only the dim lights on and the laser shutter closed >> you don't want to blast CCD with light.
-\\ [[/Operating%20Procedures|Back To Main Menu]]\\ \\ \\ **Chapter 3:** (edited 2012Aug29 by Gail and Chris)\\ **SETTING UP COMPUTER IN THE CONTROL ROOM PRIOR TO OBSERVING**\\ \\ __3.1 General Overview of Computer Setup__\\ +\\ [[/Operating%20Procedures|Back To Main Menu]]\\ \\ \\ **Chapter 3:** (edited 2012Aug29 by Gail and Chris)\\  
 + 
 +====SETTING UP COMPUTER IN THE CONTROL ROOM PRIOR TO OBSERVING==== 
 + \\ \\ __3.1 General Overview of Computer Setup__\\ 
  
   * There are six computer screens which are now horizontally arrayed.   * There are six computer screens which are now horizontally arrayed.
chara/operating_procedures.txt · Last modified: 2023/09/01 02:50 by gail_stargazer