User Tools

Site Tools


chara:operating_procedures

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
chara:operating_procedures [2018/07/05 08:24]
jones
chara:operating_procedures [2018/07/05 08:31]
jones [Preparations in the Lab Prior to Observing]
Line 51: Line 51:
 \\  \\ 
  
 +**Chapter 1:**
 ====Lab Protocol==== ====Lab Protocol====
  
Line 58: Line 59:
 \\  \\ 
 ===1.1 Lab Rules Intro=== ===1.1 Lab Rules Intro===
-\\  
 \\  The CHARA optics lab is a building within a building and is intended to provide thermal and vibrational stability. The main goal of the CHARA lab rules is to keep all optics and equipment safe from any hazards. The crucial issue being misalignment of anything. The amount of dust and dander must be kept to a minimum.\\  \\  The CHARA optics lab is a building within a building and is intended to provide thermal and vibrational stability. The main goal of the CHARA lab rules is to keep all optics and equipment safe from any hazards. The crucial issue being misalignment of anything. The amount of dust and dander must be kept to a minimum.\\ 
 \\  \\ 
 ===1.2 The Metrology Laser=== ===1.2 The Metrology Laser===
-\\  +\\ A high-powered infrared laser is used for the delay line metrology. This is an eye hazard, so before entering the lab check to make sure the red light above the door is not on. If the laser is activated, it is a must to put on IR-protective goggles. If you are not sure, wear the goggles.\\ 
-\\   +
-A high-powered infrared laser is used for the delay line metrology. This is an eye hazard, so before entering the lab check to make sure the red light above the door is not on. If the laser is activated, it is a must to put on IR-protective goggles. If you are not sure, wear the goggles.\\ +
 \\  \\ 
 ===1.3 General Lab Rules=== ===1.3 General Lab Rules===
-\\  +\\ Please remember that:\\  
-\\  +
-Please remember that:\\  +
 Procedures in the lab must be followed closely and failure to follow these rules will result in loss of lab privileges.\\  Procedures in the lab must be followed closely and failure to follow these rules will result in loss of lab privileges.\\ 
 \\   \\  
Line 88: Line 84:
 \\  \\ 
 \\  \\ 
 +**Chapter 2:** Version 2. August 27, 2012 by Judit, Version 3 January 2015 by Norm, Version ? October 2017 by Norm\\
 ====Preparations in the Lab Prior to Observing==== ====Preparations in the Lab Prior to Observing====
-\\  
-Version 2. August 27, 2012 by Judit, Version 3 January 2015 by Norm, Version ? October 2017 by Norm\\ 
 \\  \\ 
 These are routine tasks to be performed in and around the lab every evening to prepare the array for regular observations.\\  These are routine tasks to be performed in and around the lab every evening to prepare the array for regular observations.\\ 
 \\  \\ 
 ===2.1 Starting the vacuum pump for the light pipes=== ===2.1 Starting the vacuum pump for the light pipes===
-\\  
 Go into vacuum pump shack\\  Go into vacuum pump shack\\ 
  
Line 110: Line 104:
 \\  \\ 
 ===2.2 Filling IR cameras with LN2=== ===2.2 Filling IR cameras with LN2===
-\\  
 \\  \\ 
 Fill both chambers on the NIRO camera. Use the gloves and glasses provided on the shelf with the funnels and the thermos. It will normally take 1 liter of LN2 in the outer chamber and 1/2 liter in the inner chamber. Fill it until the LN2 bubbles out of the top. This camera is normally kept cool all the time, exceptions will be noted.\\  Fill both chambers on the NIRO camera. Use the gloves and glasses provided on the shelf with the funnels and the thermos. It will normally take 1 liter of LN2 in the outer chamber and 1/2 liter in the inner chamber. Fill it until the LN2 bubbles out of the top. This camera is normally kept cool all the time, exceptions will be noted.\\ 
Line 119: Line 112:
 \\  \\ 
 ===2.3 Alignment of the light path to the telescopes=== ===2.3 Alignment of the light path to the telescopes===
-\\  
 \\  \\ 
 Go into the lab. The green alignment laser on the light source table is used. To open necessary guis, use laptops or the two tablets inside lab. Tablets are the newest hand held units and are located on the west and south walls plugged into chargers.\\  Go into the lab. The green alignment laser on the light source table is used. To open necessary guis, use laptops or the two tablets inside lab. Tablets are the newest hand held units and are located on the west and south walls plugged into chargers.\\ 
Line 203: Line 195:
 \\  \\ 
 ===2.5 Starting up OPLE and Metrology=== ===2.5 Starting up OPLE and Metrology===
-\\  
 \\  \\ 
 Go to OPLE racks\\  Go to OPLE racks\\ 
Line 231: Line 222:
 \\  \\ 
 ===2.6 Final steps in the lab=== ===2.6 Final steps in the lab===
-\\  
 \\  \\ 
  
chara/operating_procedures.txt · Last modified: 2023/09/01 02:50 by gail_stargazer