chara:operating_procedures [2021/11/04 16:53] charaobs |
chara:operating_procedures [2021/11/04 18:52] charaobs |
||
---|---|---|---|
Line 78: | Line 78: | ||
Before entering the lab, you must have a reason or tasks at hand. | Before entering the lab, you must have a reason or tasks at hand. | ||
- | Lab booties/ | + | Lab booties/ |
[[: | [[: | ||
\\ | \\ | ||
Line 91: | Line 91: | ||
2.1 Starting the vacuum pump for the light pipes | 2.1 Starting the vacuum pump for the light pipes | ||
- | Go into vacuum pump shack. Flip on power switch for pump (wait for blower to go on) Open valve slowly (parallel to pipe means open) Note if fan cords are plugged into wall outlet to keep pumps cool. Note oil temperature when you start up. Oil temps below 15º C make for a labored start. There is currently a block heater on the north side of the pump and a space heater on the south side. Inform Larry if the oil temp is low and the heaters did not run to bring the temp up before starting.\\ | + | Go into vacuum pump shack. Flip on power switch for pump (wait for blower to go on) Open valve slowly (parallel to pipe means open) Note if fan cords are plugged into wall outlet to keep pumps cool. Note oil temperature when you start up. Oil temps below 15º C make for a labored start. There is currently a block heater on the north side of the pump and a space heater on the south side. Inform Larry if the oil temp is low and the heaters did not run to bring the temp up before starting.\\ |
Go into lab building, check pressures on Vacmon display. If pressure is higher than 100 torr in any of the lines, pump those lines only one at a time. Open valve a little, then come back to open fully. When all lines to be used are well below 100 torr, open all those valves. The final pressure should be 0.5 - 1.0 Torr in each line. The pump will normally bring all 6 lines down to .2-.3 Torr. The S1 and S2 lines leak the most during the day and will read the highest in the afternoon when you return, usually between 10-20 Torr in the summer and 20-30 Torr in the winter. Note any unusual vacuum readings as they can indicate a leak beyond what is normal. Sometimes a line isn't pumped down the night before and can read higher than 30 Torr. Pump the highest ones down first as stated above. | Go into lab building, check pressures on Vacmon display. If pressure is higher than 100 torr in any of the lines, pump those lines only one at a time. Open valve a little, then come back to open fully. When all lines to be used are well below 100 torr, open all those valves. The final pressure should be 0.5 - 1.0 Torr in each line. The pump will normally bring all 6 lines down to .2-.3 Torr. The S1 and S2 lines leak the most during the day and will read the highest in the afternoon when you return, usually between 10-20 Torr in the summer and 20-30 Torr in the winter. Note any unusual vacuum readings as they can indicate a leak beyond what is normal. Sometimes a line isn't pumped down the night before and can read higher than 30 Torr. Pump the highest ones down first as stated above. | ||
Line 172: | Line 172: | ||
Once all 6 are solid yellow, right click on each yellow dot, and select start. This loads the control software and will turn the button green. Once all 6 are green, you are ready to start the OPLE server. | Once all 6 are solid yellow, right click on each yellow dot, and select start. This loads the control software and will turn the button green. Once all 6 are green, you are ready to start the OPLE server. | ||
- | If using the CHAPMtoMet feature, once the OPLE server has fully started, please check sockman for CHAMPtoMet. If it is running, then MIRC is ok to start. If it is not running, log into the ople computer and run the command : CHAMPtoMet This is case sensitive. | + | If using the CHAPMtoMet feature, once the OPLE server has fully started, please check sockman for CHAMPtoMet. If it is running, then MIRC is ok to start. If it is not running, log into the ople computer and run the command : CHAMPtoMet This is case sensitive. This is not the usual mode of controlling the carts. |
Now the MIRC server is ok to start. Be sure to inform the MIRCX/ | Now the MIRC server is ok to start. Be sure to inform the MIRCX/ | ||
Line 209: | Line 209: | ||
3.7 Turn on metrology laser and home the carts | 3.7 Turn on metrology laser and home the carts | ||
- | Make sure that no one is in the lab. Turn the Laser on using the metrology laser GUI. The [Laser Power] button will go from red to green. On the Metrology Monitor GUI, click [INITIALIZE] to initialize the metrology. A window will pop up to indicate a successful initialization. Hit [OK] on the window to close it. Select REFALL and the UNK signal for each cart being used. Hit "OK" | + | <font 14px/ |
- | Home each of the active carts. The carts must be homed before observing or else fringes will not be found. Do not forget this step or endless frustration will follow. At the start of the night the carts will usually be at the back of the rails with the back switch (BS) column marked with an "X" | + | \\ |
+ | <font 14px/ | ||
+ | |||
+ | <font 14px/ | ||
+ | |||
+ | The new ople system has a home check procedure that will give the homing error of each cart. In the ople server, use the command homechk S1, S2,… to have ople check the homing accuracy. A value of a few microns is usually returned after the cart is checked. Hit ESC to clear the display and enter the next cart. If any cart has large values above 20 microns, home the cart again and check the homing until it shows low values. | ||
3.8 Synchronizing the clocks | 3.8 Synchronizing the clocks | ||
Line 223: | Line 228: | ||
See the instruments page for information about starting different instruments at the beginning of the night:\\ | See the instruments page for information about starting different instruments at the beginning of the night:\\ | ||
- | [[: | + | [[: |
\\ | \\ | ||
[[: | [[: | ||
Line 254: | Line 259: | ||
4.6 Essential Observing Links | 4.6 Essential Observing Links | ||
- | 150-Foot Solar Tower Current TowerCam Image ([[http://www.astro.ucla.edu/%7Eobs/towercam.htm|http://www.astro.ucla.edu/~obs/towercam.htm]]) a live view of the mountain. Check the clock when viewing the page as it can sometimes fail to refresh. | + | Mount Wilson HP Wren Cameras |
Caltech Millikan Library Camera ([[http:// | Caltech Millikan Library Camera ([[http:// | ||
Line 260: | Line 265: | ||
National Weather Service ([[http:// | National Weather Service ([[http:// | ||
- | CHARA telescopes spy cams and weather graph ([[http://astro.gsu.edu/~weather/chara_scopes.html|http://www.astro.gsu.edu]]) Status of each CHARA telescope and the All-sky camera. | + | Mount Wilson Ambient station |
- | Mount Wilson HP Wren Cameras ([[http://hpwren.ucsd.edu/cameras/wilson.html|http://hpwren.ucsd.edu/cameras/wilson.html]]) 360º view of mountain in color and IR | + | Jet stream forecast |
- | Aerospace Corporation weather station ([[http:// | + | IR satellite loop https://www.star.nesdis.noaa.gov/GOES/sector_band.php?sat=G17§or=psw& |
- | + | ||
- | Jet stream forecast ([[http:// | + | |
- | + | ||
- | IR satellite loop ([[http://www.wrh.noaa.gov/lox/scripts/ | + | |
California Regional Weather Server ([[http:// | California Regional Weather Server ([[http:// | ||
Clear Sky Clock ([[http:// | Clear Sky Clock ([[http:// | ||
+ | |||
+ | CHARA telescopes spy cams and weather graph ([[http:// | ||
\\ | \\ | ||
Line 283: | Line 286: | ||
5.1 Opening the Telescope Domes and enclosures\\ | 5.1 Opening the Telescope Domes and enclosures\\ | ||
\\ | \\ | ||
- | You can begin opening the telescope domes and enclosures at least two hours before sunset. The white board has times written down that the domes can be fully opened. | + | You can begin opening the telescope domes and enclosures at least two hours before sunset. The white board has times written down that the domes can be fully opened. This happens when the sun is below 35º. Before this time, the domes can be vented by partially opening them. This will help air out the domes and improve seeing at the start of the night. Hot days benefit from an earlier opening to allow the scopes to cool. Before opening the domes make sure to check the current weather conditions and the forecast to make sure conditions are safe to open and are likely to be stable as you wait for it to get dark. Also confirm that Robert or Narsi have finished the alignments in the lab or the control room as opening the domes may interupt their alignments. Call the computer room at #424 if you do not see either of them. Monitor the progress of opening the domes by turning the televisions [ON] using the telescope GUIs. Click [SPY1] to view the dome slit. In the summer, when the sun is higher overhead, use the Dome GUI for each telescope to position the domes in the anti-sun position using the RA/DEC tab and the ANTI-SUN setting for AUTODOME. This will position the dome slit opposite the sun so that you can open the slit well before sunset. You may also go to the Dome Tab on the Dome GUI, manually enter an anti-sun azimuth value from 70º-110º in the text box on the right, and press [GOTO]. This will move the dome slit to the east and opposite the sun. When the domes are facing east (and all labalignments, |
- | [NOT YET OPERATIONAL] | + | [NOT YET OPERATIONAL] On the enclosure GUI, click the [OBSERVE] button to open the lower cylinders to the observe position. Wait for the slit and enclosures to open to .300 and then wait for the sun to go down. |
5.2 Opening telescope optics\\ | 5.2 Opening telescope optics\\ | ||
Line 303: | Line 306: | ||
5.5 Slewing to a Target Using Cosmic Debris\\ | 5.5 Slewing to a Target Using Cosmic Debris\\ | ||
\\ | \\ | ||
- | It is typically dark enough to lock on your first star if TT reports ~ 1000 counts while not point at anything (sky counts) with the SpyCams turned off. This is roughly | + | It is typically dark enough to lock on your first star roughly |
5.6 Locking Tiptilt (when using lab tiptilt) | 5.6 Locking Tiptilt (when using lab tiptilt) | ||
Line 344: | Line 347: | ||
6.4 Manually stowing the telescopes | 6.4 Manually stowing the telescopes | ||
- | Unlock the tiptilt beams using the Tiptilt servo control GUI. Turn the telescope TVs to SPY1 so that you can watch the telescopes and domes stow. On the Control Tab of the telescope GUI, click [STOW]. This will send the telescope and dome to the stow position. When the telescopes reach an elevation above 50 degrees, you can begin closing the mirror covers. M1 CLOSE, M3 CLOSE, M5 CLOSE, M7 CLOSE, Finder CLOSE Note that W2 and E1? finder covers and the W1 and W2 M7 covers need a second click to close. Visually inspect the telescopes using SPY2 to make sure that the mirror covers close properly. Check the Telescope Monitor for mirror cover status. After the M1, M3 and finder mirror covers finish closing, close the dome slits by clicking [SLIT CLOSE] on the telescope control tab for each telescope dome that is open. Close the dome enclosures by clicking [CLOSE] on the cylinder GUI. Watch that each reads .000 or .001 when closed. Check that the telescopes moved to their stow positions in EL and AZ: EL 90.0 deg, AZ 55.9 deg for E1 and E2, EL 90.0 deg, AZ 99.3 deg for W1 and W2, EL 90.0 deg, AZ 82.0 deg for S1 and S2. Turn off the power for [TEL AZ], [TEL EL] and [TIP/TILT] for the active scopes using the Power GUI. Visually check all telescopes in the spycams to make sure all covers and slits are closed. Leave the telescope GUIs open until the End Night Sequence is finished. (Cosmic Debris will turn on the TVs and the Spy Cam 2 during the End Night Sequence.) If the humidity is high, make sure that the heaters are turned on. | + | Unlock the tiptilt beams using the Tiptilt servo control GUI. Turn the telescope TVs to SPY1 so that you can watch the telescopes and domes stow. On the Control Tab of the telescope GUI, click [STOW]. This will send the telescope and dome to the stow position. When the telescopes reach an elevation above 50 degrees, you can begin closing the mirror covers. M1 CLOSE, M3 CLOSE, M5 CLOSE, M7 CLOSE, Finder CLOSE Note that W2 and E1? finder covers and the W1 and W2 M7 covers need a second click to close. Visually inspect the telescopes using SPY2 to make sure that the mirror covers close properly. Check the Telescope Monitor for mirror cover status. After the M1, M3 and finder mirror covers finish closing, close the dome slits by clicking [SLIT CLOSE] on the telescope control tab for each telescope dome that is open. Close the dome enclosures by clicking [CLOSE] on the cylinder GUI. Watch that each reads .000 or .001 when closed. Check that the telescopes moved to their stow positions in EL and AZ: EL 90.0 deg, AZ 55.9 deg for E1 and E2, EL 90.0 deg, AZ 99.3 deg for W1 and W2, EL 90.0 deg, AZ 82.0 deg for S1 and S2. Turn off the power for [TEL AZ], [TEL EL] and [TIP/TILT] for the active scopes using the Power GUI and disable the scopes using the dome gui or obsgtk. Visually check all telescopes in the spycams to make sure all covers and slits are closed. Leave the telescope GUIs open until the End Night Sequence is finished. (Cosmic Debris will turn on the TVs and the Spy Cam 2 during the End Night Sequence.) If the humidity is high, make sure that the heaters are turned on. |
6.5 Send the OPLE carts to the back of the rails | 6.5 Send the OPLE carts to the back of the rails | ||
- | Click the OL and MAN buttons for the active carts on the OPLE GUI Control Tab so that the buttons turn green. Turn the carts OFF using the OPLE GUI. Click BACK on the OPLE GUI to send the carts to the back. Watch OPLE Server for Back Switch indicator to light up with an " | + | Click the OL and MAN buttons for the active carts on the OPLE GUI Control Tab so that the buttons turn green. Turn the carts OFF using the OPLE GUI. Click BACK on the OPLE GUI to send the carts to the back. Watch OPLE Server for Back Switch indicator to light up with an " |
6.6 Finish shutting down in the control room | 6.6 Finish shutting down in the control room | ||
Line 367: | Line 370: | ||
6.8 Odds and ends.\\ | 6.8 Odds and ends.\\ | ||
\\ | \\ | ||
- | Back in the Control Room: If you run into any problems during the shutdown procedures, send an email to charamnt or directly to Larry and Steve so that they can work to resolve any problems that need to be resolved promptly. Please feel free to record any details in the Observers Notebook or email Tech Report to specified groups or individual employees. Lock front and side doors of Operations Center if you are the last one in the building. Close OPLE building doors; they tend to stick open, please | + | Back in the Control Room: If you run into any problems during the shutdown procedures, send an email to charamnt or directly to Craig and Steve so that they can work to resolve any problems that need to be resolved promptly. Please feel free to record any details in the Observers Notebook or email Tech Report to specified groups or individual employees. Lock front and side doors of Operations Center if you are the last one in the building. Close OPLE building doors; they tend to stick open, please |
\\ | \\ | ||
[[: | [[: | ||