Line 94: Line 94:
  
 Go into vacuum pump shack. Flip on power switch for pump and wait for the blower to go on in about 6 seconds. Open the valve slowly after about 10-12 seconds (parallel to pipe means open). Note if fan cords are plugged into wall outlet to keep pumps cool in the summer. Note oil temperature when you start up. Oil temps are usually kept above 15º C by a block heater on the north side of the pump and a space heater on the south side. Inform Larry or Craig if the oil temp is low and the heaters did not run to bring the temp up before starting.\\ Go into vacuum pump shack. Flip on power switch for pump and wait for the blower to go on in about 6 seconds. Open the valve slowly after about 10-12 seconds (parallel to pipe means open). Note if fan cords are plugged into wall outlet to keep pumps cool in the summer. Note oil temperature when you start up. Oil temps are usually kept above 15º C by a block heater on the north side of the pump and a space heater on the south side. Inform Larry or Craig if the oil temp is low and the heaters did not run to bring the temp up before starting.\\
-Go into lab building, check pressures on Vacmon display. If pressure is higher than 100 torr in any of the lines, pump those lines only one at a time. Open each valve slowly, you will hear the air rush out as the pump pulls the air.  Slowly continue to fully open. Open each valve as the pressure is pumped down to the pressure in the next lowest line.  Ideally, you don't want to allow pressure from one line into the line of a lower pressure line. The final pressure should be around 0.5 - 1.0 Torr in each line when you leave the lab area. The pump will normally bring all 6 lines down to .2-.3 Torr after about an hour. The S1 and S2 lines leak the most during the day and will read the highest in the afternoon when you return, usually between 20-30 Torr in the summer and 15-25 Torr in the winter. Note any unusual vacuum readings as they can indicate a leak beyond what is normal. Sometimes a line isn't pumped down the night before and can read higher than 30 Torr. Pump down the highest ones first as stated above.+Go into lab building, check pressures on Vacmon display. If pressure is higher than 100 torr in any of the lines, pump those lines only one at a time. Open each valve slowly, you will hear the air rush out as the pump pulls the air. Slowly continue to fully open. Open each valve as the pressure is pumped down to the pressure in the next lowest line. Ideally, you don't want to allow pressure from one line into the line of a lower pressure line. The final pressure should be around 0.5 - 1.0 Torr in each line when you leave the lab area. The pump will normally bring all 6 lines down to .2-.3 Torr after about an hour. The S1 and S2 lines leak the most during the day and will read the highest in the afternoon when you return, usually between 20-30 Torr in the summer and 15-25 Torr in the winter. Note any unusual vacuum readings as they can indicate a leak beyond what is normal. Sometimes a line isn't pumped down the night before and can read higher than 30 Torr. Pump down the highest ones first as stated above.
  
 2.2 Filling NIRO with LN2\\ 2.2 Filling NIRO with LN2\\
Line 110: Line 110:
 Check the laser spots on the E table target at North wall of Beam Switching area. Use the laptop that resides in the corner by the East telescopes table. On Laser Filter gui, select ND 0.0 Open LASER shutter on the SHUTTERS gui and open shutters for the beams you are going to use. Using the VISBEAMS gui, move the laser to the first beam pair you will check, ie. Beams 1&2. Using the Beam Samplers gui, move beam samplers off of the beams you will align. Check each spot that is going to be used on each pair (for ex. 1&2, 2&3, 3&4, etc.) Use Pico3 gui to center laser dots on cross hairs. Be mindful of which pair was selected with VISBEAMS. (1&2-2 and 2&3-2 appear at the same spot, but different pieces of optics are involved) MIRCX alignment usually uses B1&2, B3&4, and B5&6 without the middle options of B2&3 and B4&5. Check the laser spots on the E table target at North wall of Beam Switching area. Use the laptop that resides in the corner by the East telescopes table. On Laser Filter gui, select ND 0.0 Open LASER shutter on the SHUTTERS gui and open shutters for the beams you are going to use. Using the VISBEAMS gui, move the laser to the first beam pair you will check, ie. Beams 1&2. Using the Beam Samplers gui, move beam samplers off of the beams you will align. Check each spot that is going to be used on each pair (for ex. 1&2, 2&3, 3&4, etc.) Use Pico3 gui to center laser dots on cross hairs. Be mindful of which pair was selected with VISBEAMS. (1&2-2 and 2&3-2 appear at the same spot, but different pieces of optics are involved) MIRCX alignment usually uses B1&2, B3&4, and B5&6 without the middle options of B2&3 and B4&5.
  
-Note that with the new automated alignment setup installed, the beams to the right of the beams selected will also be illuminated.  For instance, B2 is illuminated by B1 if both shutters are open and both Beam Samplers are moved away.  Close B1 shutter to see B2 illuminated by the proper beam. When you are done, use the Beam Samplers gui to put telescopes back on the appropriate beams. Note that when multiple telescope/beam configurations are requested, aligning to the secondary configuration or back up telescopes first, then finishing with the primary configuration may be more efficient. This can apply to Classic, Climb or PAVO programs.\\+Note that with the new automated alignment setup installed, the beams to the right of the beams selected will also be illuminated. For instance, B2 is illuminated by B1 if both shutters are open and both Beam Samplers are moved away. Close B1 shutter to see B2 illuminated by the proper beam. When you are done, use the Beam Samplers gui to put telescopes back on the appropriate beams. Note that when multiple telescope/beam configurations are requested, aligning to the secondary configuration or back up telescopes first, then finishing with the primary configuration may be more efficient. This can apply to Classic, Climb or PAVO programs.\\
 If the telescopes were used on the same beam on the previous night, the next steps may be very close and should not need much if any adjustment.\\ If the telescopes were used on the same beam on the previous night, the next steps may be very close and should not need much if any adjustment.\\
 \\ \\
Line 141: Line 141:
 2.3.6 M10 Alignment if there is no pop change 2.3.6 M10 Alignment if there is no pop change
  
-If there is a pop change, these steps will be performed in the control room.  Skip ahead to Section 2.4.+If there is a pop change, these steps will be performed in the control room. Skip ahead to Section 2.4.
  
 Go to a computer anywhere to check the beam remotely at the telescopes. Check Vacuum Monitor that the vacuum is below 20 torr. Open telescope gui from pull down menu. Click TV [ON] to open the camera window and click [M10AL] on the control tab to change view to the M10 alignment view, click [M7 open] to open the M7 mirror cover. Open the laser shutter, put the laser filter to OPEN or ND 0.3, and center the bright spot in beam on the black reference spot. (Note that S2 has a double spot in the center and a single spot to the lower right. The double spot is the correct one.) You may need to adjust the IRIS or the TV brightness to see the bright spot well. [BEAM] cycles the iris from open to closed and gives a good idea of where the center of the spot is. To adjust the position, use Pico 2 to select, for example, E2M10 → [MOVE] (use large steps ~ 100). Note that the up, down, left, and right buttons do no correspond to the actual directions the spot will move. When the spot is centered, click [M7 close] to close the mirror cover * click TV [OFF] to close the window. These alignments can also be done in the control room or by the observer. If they are not done with the other alignments, please let the observer know they need to be done before observing. Go to a computer anywhere to check the beam remotely at the telescopes. Check Vacuum Monitor that the vacuum is below 20 torr. Open telescope gui from pull down menu. Click TV [ON] to open the camera window and click [M10AL] on the control tab to change view to the M10 alignment view, click [M7 open] to open the M7 mirror cover. Open the laser shutter, put the laser filter to OPEN or ND 0.3, and center the bright spot in beam on the black reference spot. (Note that S2 has a double spot in the center and a single spot to the lower right. The double spot is the correct one.) You may need to adjust the IRIS or the TV brightness to see the bright spot well. [BEAM] cycles the iris from open to closed and gives a good idea of where the center of the spot is. To adjust the position, use Pico 2 to select, for example, E2M10 → [MOVE] (use large steps ~ 100). Note that the up, down, left, and right buttons do no correspond to the actual directions the spot will move. When the spot is centered, click [M7 close] to close the mirror cover * click TV [OFF] to close the window. These alignments can also be done in the control room or by the observer. If they are not done with the other alignments, please let the observer know they need to be done before observing.
Line 231: Line 231:
 3.9. Beacon Alignments 3.9. Beacon Alignments
  
-The beacons wil<font 14px/Arial,Helvetica,sans-serif;;inherit;;inherit>l need to be aligned before g</font>oing on sky and are usually done after the lab is aligned, after the pops have been changed and M10 mirrors aligned, before sunset and again before slewing. Make sure the carts are not at the front when performing these alignments or the labao alignments will be off.  Move the carts to 5m or farther from the home switch. The beacon alignments consist of opening the proper mirror, beacon and fiber covers, turning on the beacons and tel WFS cameras and labao displays, and aligning and focusing the red and blue beacons to the respective boxes on the tel WFS and labao. The obsgtk will display a green message at the bottom to confirm each alignment sequence has completed.+The beacons wil<font 14px/Arial,Helvetica,sans-serif;;inherit;;inherit>l need to be aligned before g</font>oing on sky and are usually done after the lab is aligned, after the pops have been changed and M10 mirrors aligned, before sunset and again before slewing. Make sure the carts are not at the front when performing these alignments or the labao alignments will be off. Move the carts to 5m or farther from the home switch. The beacon alignments consist of opening the proper mirror, beacon and fiber covers, turning on the beacons and tel WFS cameras and labao displays, and aligning and focusing the red and blue beacons to the respective boxes on the tel WFS and labao. The obsgtk will display a green message at the bottom to confirm each alignment sequence has completed.
  
 In the WFS tab of the telescope GUI or the CONTROL tab of the obsgtk, turn on the red LED, open the fiber covers, then beacon flat covers. The CAMERALINK and WFS server are now part of Bootlaunch script and the ANDOR camera power should always be on in the POWER gui. Open M5 and M7 covers. In the WFS tab of the telescope GUI or the CONTROL tab of the obsgtk, turn on the red LED, open the fiber covers, then beacon flat covers. The CAMERALINK and WFS server are now part of Bootlaunch script and the ANDOR camera power should always be on in the POWER gui. Open M5 and M7 covers.
Line 250: Line 250:
 If the spots do not show at all in the labao, the scope dichroic is likely out of alignment. Turn on the lab laser and set it to ND 4.0. Look for additional spots in the ACQ window that are not from the beacon. Use the Dichroic controls to make the laser spots match the blue beacon spots on the ACQ camera view. Up is to the upper right in the ACQ view. If they are way off or not visible in the ACQ, you can hit the button for the appropriate dichroic in the HUT gui and it will set the dichroic to its last saved default position. If the spots do not show at all in the labao, the scope dichroic is likely out of alignment. Turn on the lab laser and set it to ND 4.0. Look for additional spots in the ACQ window that are not from the beacon. Use the Dichroic controls to make the laser spots match the blue beacon spots on the ACQ camera view. Up is to the upper right in the ACQ view. If they are way off or not visible in the ACQ, you can hit the button for the appropriate dichroic in the HUT gui and it will set the dichroic to its last saved default position.
  
-Note the focus term on both the TWFS and LABAO GUIs or obsgtks. The next steps will minimize both focus terms. Start with the (BEACON FOC) button on the ALIGN tab of the LABAO GUI or (FOCUS) LABAO: on obsgtk, wait until the procedure finishes. Then use the (FOCUS WFS) button on the ALIGN tab of the TWFS GUI or (FOCUS) TELWFS: on the obsgtk and wait for completion. Note that focusing the beacons does not work when the spots are not reasonably centered. Always get the spots well into the boxes first before focusing. Sometimes it helps to repeat the scope dichroic alignment and focus as each needs the other to be close to align well and large changes in the labao focus can put the TWFS out of alignment also.  As the scopes are cooling, these alignments will drift and will need to be done before slewing to the first target.+Note the focus term on both the TWFS and LABAO GUIs or obsgtks. The next steps will minimize both focus terms. Start with the (BEACON FOC) button on the ALIGN tab of the LABAO GUI or (FOCUS) LABAO: on obsgtk, wait until the procedure finishes. Then use the (FOCUS WFS) button on the ALIGN tab of the TWFS GUI or (FOCUS) TELWFS: on the obsgtk and wait for completion. Note that focusing the beacons does not work when the spots are not reasonably centered. Always get the spots well into the boxes first before focusing. Sometimes it helps to repeat the scope dichroic alignment and focus as each needs the other to be close to align well and large changes in the labao focus can put the TWFS out of alignment also. As the scopes are cooling, these alignments will drift and will need to be done before slewing to the first target.
  
 See the instruments page for information about starting different instruments at the beginning of the night: \\ [[:chara:instruments|Instruments: CLASSIC, CLIMB, MIRC-X/MYSTIC, PAVO]] \\  \\ [[:chara:operating_procedures|Back to Main Menu]] \\  \\  \\ **Chapter 4: ** See the instruments page for information about starting different instruments at the beginning of the night: \\ [[:chara:instruments|Instruments: CLASSIC, CLIMB, MIRC-X/MYSTIC, PAVO]] \\  \\ [[:chara:operating_procedures|Back to Main Menu]] \\  \\  \\ **Chapter 4: **
Line 285: Line 285:
 4.6 Essential Observing Links 4.6 Essential Observing Links
  
-Mount Wilson HP Wren Cameras ([[http://hpwren.ucsd.edu/cameras/wilson.html|http://hpwren.ucsd.edu/cameras/S/SD/wilson.html]]) 360º views of mountain in color and B&W IR modes+Mount Wilson HP Wren Cameras ([[http://hpwren.ucsd.edu/cameras/S/SD/wilson.html|http://hpwren.ucsd.edu/cameras/S/SD/wilson.html]]) 360º views of mountain in color and B&W IR modes
  
 National Weather Service ([[http://forecast.weather.gov/MapClick.php?site=lox&textField1=34.2231&textField2=-118.0587&smap=1#.VKsuq2TF8rO|http://forecast.weather.gov]]) Mount Wilson weather and 5 day forecast National Weather Service ([[http://forecast.weather.gov/MapClick.php?site=lox&textField1=34.2231&textField2=-118.0587&smap=1#.VKsuq2TF8rO|http://forecast.weather.gov]]) Mount Wilson weather and 5 day forecast
chara/operating_procedures.txt · Last modified: 2023/09/01 02:50 by gail_stargazer