Line 17: | Line 17: | ||
* All pops were out and PERI positions lost → All 6 PERI axes had to be homed and AFTER THAT set pop5 first with POPPERIGTK and adjusted M10 as needed. | * All pops were out and PERI positions lost → All 6 PERI axes had to be homed and AFTER THAT set pop5 first with POPPERIGTK and adjusted M10 as needed. | ||
- | Additional Notes After Power Outage on August, 17, 2021 and June 2022. | + | Additional Notes After Power Outage on August, 17, 2021, June 2022, Feb 2024. |
* Reinitialize the NIRO Filter Wheel. Open the niro_filter_gtk and click REINIT. Check to see if the indicator wheel on the NIRO camera is pointing to the correct filter after it is homed. Do not turn the wheel by hand. If it points to the wrong filter, home the filter wheel again, and compare counts for each filter (or look for metrology light in J-band) to confirm the correct filters are in position. Then loosen the screw on the indicator wheel and align so that it points to the correct filter label that is currently in. | * Reinitialize the NIRO Filter Wheel. Open the niro_filter_gtk and click REINIT. Check to see if the indicator wheel on the NIRO camera is pointing to the correct filter after it is homed. Do not turn the wheel by hand. If it points to the wrong filter, home the filter wheel again, and compare counts for each filter (or look for metrology light in J-band) to confirm the correct filters are in position. Then loosen the screw on the indicator wheel and align so that it points to the correct filter label that is currently in. | ||
Line 34: | Line 34: | ||
* load the new module: \\ sudo modprobe e1000e | * load the new module: \\ sudo modprobe e1000e | ||
* ensure the module is persistent across a reboot: \\ sudo dpkg-reconfigure linux-image-$(uname -r) | * ensure the module is persistent across a reboot: \\ sudo dpkg-reconfigure linux-image-$(uname -r) | ||
+ | * The STST chiller will power back on after an outage, but the cooler does not start automatically. Press the settings button to start the cooling again. | ||
+ | |||
+ | <font inherit/ | ||
+ | |||
+ | <font inherit/ | ||
+ | |||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | * <font inherit/ | ||
+ | |||
+ | <font inherit/ | ||
+ | |||
+ | Notes added Sept 20, 2024: | ||
+ | |||
+ | * Check the Exhibit Hall Displays. If the slides are not displaying correctly, log on and reboot each computer: | ||
+ | * ssh -X pi@ehpi01 | ||
+ | * Enter wifi password | ||
+ | * sudo reboot | ||
+ | * The ehpi's go from 01 to 10. | ||
+ | * You can reboot all 10 of the displays in the exhibit hall using the following command sequence: | ||
+ | * Log onto the control network (any machine) as user " | ||
+ | * Issue the command: " | ||
+ | |||
+ | Facitilities Checks: | ||
+ | |||
+ | * The HVAC unit in the pump house looses its memory during a power outage. Power cycle the HVAC unit to reconnect with the thermostat. | ||