Make sure the vacuum is below 5 torr in the pipe.
Proceed with the usual steps up to LAB DICH alignment with labao.
Adjust by hand DM tilt to front side of front rail target
Cart at the back. Adjust BRT using brtgtk to back side of front rail target.
Use Obsgtk to send M7 to default position. (this is just in case, it did not go there at the end of night)
Do M10 alignment. Close laser shutter. (Dome shutter has to be closed daytime, and dome light off, spycam off [switch to M10 TV] )
Set laser to ND=4 (laser shutter closed)
Switch on ACQ camera, watch the bright beacon spot and move it to the hole
Align beacon to twfs (laser shutter closed)
(open M5 cover) Find beacon on labwfs, if not seen, open laser shutter and watch the laser spots appearing in ACQ TV.
use the SCOPE DICH buttons: UP, DOWN, LEFT or RIGHT to overlap laser spots with the closest beacon spots
Align SCOPE DICH to labwfs.
Adjust Beacon focus to labwfs: hit BEAC FOC in labao gui. After that adjust focus to twfs: hit FOCUS WFS in twfs gui.
Now you are set for labwfs Coude, but for the scopes with original M7 cones it is better to start with an Acquisition Coude instead of labwfs Coude.
As of 6/1/2021 only E2 has the new cones.