chara:coude_alignment_procedure [2021/06/02 18:59]
gail_stargazer
chara:coude_alignment_procedure [2021/06/02 19:05]
gail_stargazer
Line 3: Line 3:
 Written by Judit Sturmann on 2021 June 1. Written by Judit Sturmann on 2021 June 1.
  
-==== Preparation  ====+==== Preparation ====
  
   * Make sure the vacuum is below 5 torr in the pipe.   * Make sure the vacuum is below 5 torr in the pipe.
Line 50: Line 50:
   * Go to the AOB ENG tab on the hut engineering gui and save the new default M7 position by hitting the “DICHROIC POSITION” (or similar) button, and then “SAVE ..(stg)”. [<this button is in the same row as the DICHROIC POSITION button.] A new configuration file is now saved, that also includes the tilts of beacon flat, AOB splitter, and focuses.   * Go to the AOB ENG tab on the hut engineering gui and save the new default M7 position by hitting the “DICHROIC POSITION” (or similar) button, and then “SAVE ..(stg)”. [<this button is in the same row as the DICHROIC POSITION button.] A new configuration file is now saved, that also includes the tilts of beacon flat, AOB splitter, and focuses.
  
-====    Revision History   ====+==== Revision History ====
  
-  * Gail Schaefer added to wiki page on 6/2/2021.+  * 2021Jun01 - Document written by Judit Sturmann. 
 +  * 2021Jun02 - Gail Schaefer added to wiki page
 +  * 2021Jun02 - Removed link for [[https://docs.google.com/document/d/1UY5C8Pkbi_yd448aF_TXXE9KFkwjd5VK3LALvkFahjQ/edit|old Coude alignment procedure]].
  
  
chara/coude_alignment_procedure.txt · Last modified: 2021/06/02 19:11 by gail_stargazer