User Tools

Site Tools


chara:trouble_shooting

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
chara:trouble_shooting [2022/01/18 22:32]
charaobs
chara:trouble_shooting [2022/01/18 22:47]
charaobs
Line 97: Line 97:
 <font 14px/Arial,Helvetica,sans-serif;;#333333;;inherit>6. Click OVERRIDE OFF, go to the AUTO tab and press AUTO, then NEXT (also in the obsgtk; this will restore the original star's demand position to the scope).</font> <font 14px/Arial,Helvetica,sans-serif;;#333333;;inherit>6. Click OVERRIDE OFF, go to the AUTO tab and press AUTO, then NEXT (also in the obsgtk; this will restore the original star's demand position to the scope).</font>
  
-<font 14px/Arial,Helvetica,sans-serif;;#333333;;inherit>7. When you have time, go to the scope and reset the limit switch; otherwise, it will stop each time you pass AZ 270/90.  The LED will show red when on the limit switch and is tripped, ie. limiting motion of the scope.  The LED will be yellow if it has tripped and is in the caution range, but not on a limit switch.  A fine Allen key can be used to push the internal reset button. It will turn the LED green when restored.</font>+<font 14px/Arial,Helvetica,sans-serif;;#333333;;inherit>7. When you have time, go to the scope and reset the limit switch; otherwise, it will stop each time you pass AZ 270/90. The LED will show red when on the limit switch and is tripped, ie. limiting motion of the scope. The LED will be yellow if it has tripped and is in the caution range, but not on a limit switch. A fine Allen key can be used to push the internal reset button. It will turn the LED green when restored.</font>
  
 ==== The Telescope won't track ==== ==== The Telescope won't track ====
Line 109: Line 109:
 ==== Dome Server Restart ==== ==== Dome Server Restart ====
  
-Dome servers are now started using the bootlaunch_master command.  Kill the server by finding the process ID with bootlaunch_master and restart it with bootlaunch_master also.  The manual process that has been superceded is listed below.+Dome servers are now started using the bootlaunch_master command. Kill the server by finding the process ID with bootlaunch_master and restart it with bootlaunch_master also. The manual process that has been superceded is listed below.
  
 To manually start the dome server: To manually start the dome server:
Line 240: Line 240:
  
 Sometimes when observing, the dome will not follow the telescope during a slew. This can happen when the Autodome feature is not turned on. Click the ON button on the MAIN tab of the telescope gui to enable it. This may happen after a server restart so always check the dome position with the spycam during a slew after a server restart. Also make sure the target position of the dome matches the telescope's position. If not, it will insist on being in the wrong place. If it is not at the same AZ as the scope, manually move it until it is centered on the telescope in spycam 1. If the dome AZ does not read the same as the telescope AZ, enter the scope AZ in the position box of the DOME tab of appropriate dome server and hit the INIT POS button to tell it at what AZ it is. \\  \\ Sometimes when observing, the dome will not follow the telescope during a slew. This can happen when the Autodome feature is not turned on. Click the ON button on the MAIN tab of the telescope gui to enable it. This may happen after a server restart so always check the dome position with the spycam during a slew after a server restart. Also make sure the target position of the dome matches the telescope's position. If not, it will insist on being in the wrong place. If it is not at the same AZ as the scope, manually move it until it is centered on the telescope in spycam 1. If the dome AZ does not read the same as the telescope AZ, enter the scope AZ in the position box of the DOME tab of appropriate dome server and hit the INIT POS button to tell it at what AZ it is. \\  \\
-If the dome does not turn at all, even with the manual controls on the telescope or dome guis, the control may be set to manual on the control box. This can happen if there was work done at the dome during the day. If the dome opens, but does not turn, check to see that control of the dome rotation is in the computer position and not manual on the dome rotation controller box just inside the door of the bunker. Sometimes the drive wheel jumps in the track and cannot turn the dome, even when the motor works.  This will need to be fixed during the day.+If the dome does not turn at all, even with the manual controls on the telescope or dome guis, the control may be set to manual on the control box. This can happen if there was work done at the dome during the day. If the dome opens, but does not turn, check to see that control of the dome rotation is in the computer position and not manual on the dome rotation controller box just inside the door of the bunker. Sometimes the drive wheel jumps in the track and cannot turn the dome, even when the motor works. This will need to be fixed during the day.
  
 ==== Dome does not open ==== ==== Dome does not open ====
Line 285: Line 285:
  
   * Good metrology signals are important to the proper positioning of the carts. Monitor the signal strength by running [RUN MULTIPLE] on the Metrology Monitor. Place the windows above the TV windows for each scope you are using. They should show white sine waves that are around the height of the window. Erratic, fluctuating waves indicate self-interference or a weak signal. This may cause the carts to lose their place as the signal strength falls too low. Red waves indicate that some displayed signal has gone too low and the carts will all need to be homed. A careful adjustment of the MET2 mirror can sometimes bring the signal back. Do not adjust the MET1 mirror.   * Good metrology signals are important to the proper positioning of the carts. Monitor the signal strength by running [RUN MULTIPLE] on the Metrology Monitor. Place the windows above the TV windows for each scope you are using. They should show white sine waves that are around the height of the window. Erratic, fluctuating waves indicate self-interference or a weak signal. This may cause the carts to lose their place as the signal strength falls too low. Red waves indicate that some displayed signal has gone too low and the carts will all need to be homed. A careful adjustment of the MET2 mirror can sometimes bring the signal back. Do not adjust the MET1 mirror.
-  * To home the carts, turn off the [OL] and [MAN] buttons on each cart and it will automatically return to the front switch. If the cart has no issue, it will arrive at the target position of 0m and the home switch at the same time. The X in the OPLE server under the HM will indicate it has stopped on the home switch. If a cart does not reach the home switch when it returns to position 0m, it was lost and likely the cause of the difficulty in finding fringes.  The X does not guarantee the cart has retained its home position.  This can only be done by using the CHECK button on the ople gui or by typing the command "homechk S1" into the ople server.  When the error value is displayed on the ople server, hit ESC to clear the display. Click on the [OL] and [MAN] buttons and hit [TRACK] to send the cart to the desired cart position.+  * To home the carts, turn off the [OL] and [MAN] buttons on each cart and it will automatically return to the front switch. If the cart has no issue, it will arrive at the target position of 0m and the home switch at the same time. The X in the OPLE server under the HM will indicate it has stopped on the home switch. If a cart does not reach the home switch when it returns to position 0m, it was lost and likely the cause of the difficulty in finding fringes. The X does not guarantee the cart has retained its home position. This can only be done by using the CHECK button on the ople gui or by typing the command "homechk S1" into the ople server. When the error value is displayed on the ople server, hit ESC to clear the display. Click on the [OL] and [MAN] buttons and hit [TRACK] to send the cart to the desired cart position.
  
 ===== Beam Samplers ===== ===== Beam Samplers =====
Line 460: Line 460:
  
  \\  \\
-Last updated 2017-04-12+Last updated 2021-01-18 by Norm Vargas
  
  
chara/trouble_shooting.txt ยท Last modified: 2023/11/21 01:42 by charaobs